P460/P360 Memory Scanners Product Reference Guide
asserted within two seconds (default), the scanner issues an error indication and discards
the data.
RTS/CTS OPTION 2
When Option 3 is selected, the scanner asserts RTS prior to any data transmission,
regardless of the state of CTS. The scanner waits up to two seconds (default) for CTS to
be asserted. If CTS is not asserted during this time, the scanner issues an error indication
and discards the data. The scanner deasserts RTS when transmission is complete.
RTS/CTS OPTION 3
Software Handshaking
This parameter offers control of the data transmission process in addition to, or instead of,
that offered by hardware handshaking. There are five options.
If Software Handshaking and Hardware Handshaking are both enabled, Hardware
Handshaking takes precedence.
None
When this option is selected, data is transmitted immediately.
NONE