Chapter 3. Using the Monitor/Debug Firmware 3-25
Commands
LR Loop Read
Usage: LR<width> addr
The LR command continually reads the data at addr until a key is pressed. The optional <width>
specifies the size of the data to be read. If no <width> is specified, the command defaults to reading
word sized data.
Example:
To continually read the word data from address 0xFFF2_0000, the command is:
lr FFF20000