Motorola T3 Guía de usuario Pagina 20

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 24
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 19
Motorola, Inc Page 20 of 24
XLP-6824/XLP-7038
Power is managed at two distinct hardware locations. Power applied on the premises wire -
between the switch and the CPE - is controlled by the power control circuitry inside the XLP
master switch. Power over Ethernet on the XLP client is controlled by a PoE controller.
Cmd: show interface dsl power status
Use this command to view the state of line power on the switch.
Power States:
disabled - Port is disabled
searching - Port is in Discovery (checking the line for a valid CPE)
powering - Port is on
Fault States:
none - Port is normal
disconnect - Port is under-current, a CPE has been disconnected
short circuit - Port current is nearly “full scale” meaning there’s a short
over current - Port current is more than it should be, but not quite full scale
current imbalance - Port GFI activated. More current in one leg than the other leg
Cmd: show interface remote power status
Use this command to view the state of the PoE port on the CPE.
Detection state:
disabled - Port is disabled
searching - Port is in Discovery (port is checking for a valid 802.3af PD)
powering - Port is on
other - See fault states for details
Fault States:
none - Port is normal
disconnect - PD has been disconnected
(XLP-6800 only)
voltage - PoE voltage is outside the 802.3af specified range
current - PoE current exceeds the 802.3af specification
thermal - PoE controller temperature >150C
Vista de pagina 19
1 2 ... 15 16 17 18 19 20 21 22 23 24

Comentarios a estos manuales