Vista de pagina 68
User Preferences 6 - 7
User Parameter Pass Through
Parameter # F1h 71h
Enable this to send user-defined parameter bar codes (see User-Defined Parameter Bar Code Format) as
normal decode data in decode data packets for SSI and SNAPI hosts (see Decode Data Format).
User-Defined Parameter Bar Code Format
Code 128 bar codes with:
<FNC3><L><data>
or
<FNC3><B><12 bytes of data>
Decode Data Format
<0xf3><L><data>
or
<0xf3><B><12 bytes of data>
Note that the
B type only works with 12 bytes of data.
A normal decode beep sounds upon a successful decode of a user-defined parameter bar code.
Enable User Parameter Pass Through
(01h)
*Disable User Parameter Pass Through
(00h)