Motorola SYMBOL MS320X Especificaciones Pagina 84

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 428
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 83
6 - 22 DS457 Fixed Mount Imager Integration Guide
Multicode Mode
Parameter # F1h, A5h
Enable this parameter to allow multiple bar codes to decode upon one trigger event based on the programmed
multicode expression. The imager reports a successful decode and provides user indication only if it decodes
all bar codes indicated by the multicode expression, otherwise the decode fails. Bar codes are transmitted in
the order defined in the multicode expression. Disable this to operate in normal decode mode.
This mode operates in Level trigger mode only. Also disable Continuous Bar Code Read. If you enable this
mode, always orient the imager at the same distance and angle (perpendicular).
*Disable Multicode Mode
(00h)
Enable Multicode Mode
(01h)