Chapter 13: Scanners
UPC A Settings
Psion Mobile Devices Developers Guide
118
Decoded Laser Scanner
Scanner setting key = Barcode\UPCA\Decoded
EV15 1D Imager And E1022 1D Imager
Scanner setting key = Barcode\UPCA\ICSP
5x80 Imager
Scanner setting key = Barcode\UPCA\HHP
Imager
Scanner setting key = Barcode\UPCA\Imager
Scanner Setting Name Minimum Maximum Default Values GUI Name
Enabled 0 = off 1 = on 1 Enabled
UPCA Transmit Check Digit 0 = off 1 = on 1 UPC-A Check Digit
UPCA Preamble 0 2 1 0 = None
1 = System char
2 = Country code and system char
UPC-A Preamble
Scanner Setting Name Minimum Maximum Default GUI Name
Enabled 0 = off 1 = on 1 Enabled
Transmit Check Digit 0 = off 1 = on 1 Transmit Check Digit
Transmit Number System 0 = off 1 = on 1 Transmit Number System
Transmit as EAN-13 0 = off 1 = on 0 Convert to EAN 13
Scanner Setting Name Minimum Maximum Default GUI Name
Enabled 0 = off 1 = on 1 Enabled
Check Digit 0 = off 1 = on 1 Check Digit
Number System 0 = off 1 = on 1 Transmit Number System
2 Digit Addendum 0 = off 1 = on 0 Addendum Add-on 2
5 Digit Addendum 0 = off 1 = on 0 Addendum Add-on 5
Addendum Required 0 = off 1 = on 0 Addendum Required
Addendum Separator 0 = off 1 = on 1 Addendum Separator