Chapter 13: Scanners
UPC/EAN Shared Settings
Psion Mobile Devices Developers Guide
122
Decoded Laser Scanner
Scanner setting key = Barcode\UPC_EAN\Decoded
EV15 1D Imager And E1022 1D Imager
Scanner setting key = Barcode\UPC_EAN\ICSP
Note 1: Omnii only.
5x80 Imager
Scanner setting key = Barcode\UPC_EAN\HHP
Scanner Setting Name Minimum Maximum Default Values GUI Name
Bookland Enabled 0 = off 1 = on 0 Enable Bookland EAN
Supplementals 0 2 0 0 = Ignore
1 = Decode
2 = Autodiscriminate
Supplementals
Supplemental Redundancy 2 20 20 Supp. Redundancy
Security Level 0 3 0 Security Level
Linear Decode 0 = off 1 = on 0 Linear Decode
UPC Half Block Stitching 0 = off 1 = on 1 UPC Half Block Stitching
Scanner Setting Name Minimum Maximum Default Values GUI Name
Addendum 0 1 0 Addendum
Addendum Add-on 2 0 = off 1 = on 0 Addendum Add-on 2
Addendum Add-on 5 0 = off 1 = on 0 Addendum Add-on 5
Addendum Security 0 100 10 Addendum Security
GTIN Compliant 0 = off 1 = on 0 GTIN Compliant
Reading Range
1
0 1 1 0 = Normal
1 = Extended
Reading Range
Scanner Setting Name Minimum Maximum Default GUI Name
UPC-A EAN-13 Extended Coupon
Code
0 = off 1 = on 1 Extended Coupon Code
Comentarios a estos manuales