Vista de pagina 72
DEBUG MONITOR COMMANDS
M68CPU32BUG/D REV 1 3-43
MM Memory Modify MM
EXAMPLES
CPU32Bug>MM 3100<CR> Access location 3100.
00003100 1234?<CR>
00003102 5678? 4321<CR> Modify memory.
00003104 9ABC? 8765^<CR> Modify memory and backup.
00003102 4321?<CR> No change, backup still utilized.
00003100 1234? abcd.<CR> Modify memory and exit.
CPU32Bug>MM 3001;LA<CR> Longword access to location 3001.
00003001 CD432187?<CR> Alternate location accesses.
00003009 00068010? 68010+10=<CR> Modify and re-open location.
00003009 00068020?<CR> No change, re-open still utilized.
00003009 00068020? .<CR> Exit MM.
CPU32Bug>MM 4000<CR> Modify WORDs starting at $4000.
00004000 0000? ’A’<CR> Enter ASCII ’A’, right justified.
00004002 0000? ’B’<CR> Enter ASCII ’B’, right justified.
00004004 0000? ’CD’<CR> Enter ASCII ’CD’, right justified.
00004006 0000? ’EFG’<CR> Enter ASCII ’FG’, right justified. Note the ’E’ is
truncated due to right justified WORD size!
00004008 0000? .<CR> Exit MM.
CPU32Bug>MD 4000<CR>
00004008 0041 0042 4344 4647 0000 0000 0000 0000 .A.BCDFG........
CPU32Bug>
The DI option activates the one-line assembler/disassembler. All other options are invalid if DI is
selected. The contents of the specified memory location is disassembled and displayed and the
user prompted for an input with a question mark ( ? ). At this point the user has three options:
Enter <CR> – This closes the present location and continues with disassembly of the
next instruction. The instruction is unchanged.
Enter a new source instruction followed by <CR> – This actuates the assembler to
assemble the new instruction and generate a disassembly of the object code generated.
Enter <CR> – This closes the present location and exits the MM command.
If a new source line is entered (second option above), the present line is erased and replaced by
the new source line.
If an error is found during assembly, the caret symbol (^) appears below the suspect field
followed by an error message. The accessed location is redisplayed.