Installation 2 - 7
Connecting the MiniScan
To connect the MiniScan to the host, connect the scanner cables in the order shown in Figure 2-7.
Figure 2-7
Typical Connection Diagram
Figure 2-8
Trigger Jack Connector Pins
1
4
5
2
Trigger or Photo
Sensor (Optional)
To Host
3
Beeper
(Optional)
Trigger Jack (Optional)
See Figure 2-8
Male jack shown for reference
Note: Due to many variations of
jack and socket styles, identify
terminals as shown before
soldering leads.
1
1
2
2
3
3
Insertion
Direction
1 - Ground (Sleeve)
2 - Battery (Middle Contact)
3 - Trigger (Tip)
1 - Ground (Sleeve)
2 - Vcc (Middle Contact)
3 - Trigger (Tip)