8.22 Save Memory SV
Format:
SV StartAddress EndAddress|+Length Path&Filename.rec|.s19
SVL StartAddress EndAddress|+Length Path&Filename.rec|.s19
or
SV StartAddress EndAddress|+Length Path&Filename.obj|.bin
SVL StartAddress EndAddress|+Length Path&Filename.obj|.bin
Command to save a block of memory to a file in S19 or binary image format. The SV form saves
MCU-controlled memo ry, SVL saves only local memory.
The start address of the block to be saved must be stated explicitly ( an asterisk will not do). Either
the end address, or a length must then be specified, followed by the path and name of the file. The
extension determines whether the data is saved in S19 format or as a binary object file.
The path part of the filename may be shortened by the use of tokens - see Path Tokens on page 41.
If path and filename include spaces, then the whole argument string must be enclosed in single or
double quotation marks.
The following example saves the memory from $B600 to $B6CE (inclusive) to the file Test1.S19:
SV B600 B6CE "[MyDocs]\68HC908\Test1.s19"
If successful, a 'Saving complete' message will appear in the Output Window:
To save having to type the file name and path, this command may be executed automatically from the
Actions menu with one of the four items: Save MCU to S19, Save MCU to Binary, Save Local to S19,
Save Local to Binary. The word 'SV' or 'SVL', as appropriate, followed by the full file name, is then
written to the command edit box, and the command is executed. A speedbutton is provided for the
common operation of saving MCU-controlled memory to an S19 file.