Motorola AP-51XX Manual de usuario Pagina 487

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 698
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 486
8-153
AP51xx>admin(system.access)>set
Description:
Defines the permissions to access the access point applet, CLI, SNMP as well as defining their timeout values.
Syntax:
For information on configuring access point access settings using the applet (GUI), see Configuring Data Access on page 4-9.
set applet Defines the applet HTTP/HTTPS access parameters.
app-timeout <minutes> Sets the applet timeout. Default is 300 Mins.
cli Defines CLI Telnet access parameters. Enables/disables access from lan
and wan.
ssh Sets the CLI SSH access parameters.
auth-timout <seconds> Disables the radio interface if no data activity is detected after the interval
defined. Default is 120 seconds.
inactive-timeout <minutes> Inactivity interval resulting in the AP terminating its connection.
Default is 120 minutes.
snmp Sets SNMP access parameters.
admin-auth Designates a Radius server is used in the authentication verification.
server <ip> Specifies the IP address the Remote Dial-In User Service (RADIUS) server.
port <port#> Specifies the port on which the RADIUS server is listening. Default is 1812.
secret <pw> Defines the shared secret password for RADIUS server authentication.
mode <mode> Enables/disables the access point message mode.
msg Defines the access point login message text.
Vista de pagina 486