Locomotive decoders 30s series English
Page 27
Name of CVs /
Registers
CV-
no.
Reg.
no.
Input value
(Default)
Remarks and Tips
Version 7 --- --- Read only in DCC format!
Programming
a SUSI module
(LD-G-33,
LD-G-34 and
LD-W-33 only)
7 02 9 To start the programming of a
CV of a SUSI module. The next
CV set, is valid for the SUSI-
module. The CV-no. is entered
without a leading "9".
Example: Programming the CV#902 of the SUSI module to the value "8":
By entering the value "9" for CV#7 of the decoder, the programming mode is
started. Next the CV of the SUSI module is chosen by entering a "2" or "02"
(leaving out the leading "9") and for the CV#902 the value "8" is set. The
decoder automatically goes back to the programming of it´s own CVs. In order
to programm another CV of the SUSI module, the operation has to be repeated
completely.
Manufacturer 8 --- (62) Read only in DCC format!
Reset 8 03 0 ... 255 Any input value restores the
settings in state of delivery.
9 48 0, 1 Numerical value*
(0) 31,5 kHz 0
Motor
frequency
(LD-G-31,
LD-G-33 and
LD-G-34 only)
17 kHz 1
Tip: In case that the locomotive´s driving characteristics are not satisfactory with
the standard setting of 31,5 kHz, the motor frequency of 17 kHz should be chosen.
9 48 0, 1 Numerical value*
(0) 480 Hz 0
Motor
frequency
(LD-W-32 only)
60 Hz 1
Tip: In case that the locomotive´s driving characteristics are not satisfactory with
the standard setting of 480 Hz, the motor frequency of 60 Hz should be chosen.
Comentarios a estos manuales