Modem Configuration and Profile
3-240 AT Commands Reference Manual January 31, 2007
The following table shows the S102 parameters.
Example
ATS102? <enter>
030
OK
ATS102=100 <enter>
OK
ATS102? <enter>
100
OK
(This means if there is data for transmission to the terminal, the G24 drops the Wakeup Out line,
waits 100 ms. and then sends data to the terminal.)
S100, Set Minimum Time for Terminal to Fall into Sleep Mode
ATS100 is a terminal minimum time limit for entering sleep mode.
In order to limit the number of interrupts on the DTE side and reduce data sending delay time on
our side, G24 sends wakeup-out pulse when the interval between one burst of sent/received data
to the other is bigger than specified in ATS100.
Command Type Syntax Response/Action Remarks
Set
ATS102 = <value> OK
The Set command sets the delay before
sending data to the terminal, and
defines a period between sending the
wakeup signal and sending data to the
terminal.
Read
ATS102? <value>
OK
The Read command returns the current
value.
Table 3-165: S102 Parameters
<Parameter> Description
<value> 0 <= value <= 255
The default value is 30 ms.
Command Type Syntax Response/Action Remarks
Set
ATS100=<delta> OK
Or
+CME ERROR: <err>
The set command sets the terminal
minimum time limit for entering sleep
mode.
Read
ATS100? <delta>
OK
The Read command returns the current
ATS100 value.