SG4000 Installation and Operation Manual
Appendix B
Torque Specifications
Torque specifications are valid for all models of the SG4000 node.
Torque
Fastener Screw Size Wrench Size
In-lbs Ft-lbs
Nm
Strand clamp/pedestal
mounting
5/16–18 1/2 inch 120–144 10–12 13.6–16.3
Housing/lid closure
5/16–18 1/2 inch 144 12 16.3
External/internal port plugs
5/8–24 1/2 inch 25–40 2.1–3.3 2.8–4.5
Port seizure screw
#8–32 1/16 inch 11–12 0.9–1.0 1.2–1.4
RF module chassis
#8–32 1/4 inch 8–12 0.6–1.0 .8–1.4
RF module chassis cover
#4–40 1/4 inch 6–8 0.5–0.6 .7–.8
Optics modules
#6–32 1/4 inch 15–17 1.2–1.4 1.6–1.9
Optics module chassis cover
#4–40 1/4 inch 15–17 1.2–1.4 1.6–1.9
Power supplies
#6–32 1/4 inch 10–12 0.8–1.0 1.1–1.4
Service cable fitting into
housing lid fiber entry
5/8–24 3/4 inch 60–72 5–6 6.8–8.1
Strand cable fitting into
housing base port entry
5/8–24 3/4 inch 60–72 5–6 6.8–8.1