Vista de pagina 72
SG4000 Installation and Operation Manual
Section 4
Modules
This section identifies and provides detailed information on all modules that you can use with
the SG4000. It also discusses their installation, removal, and cleaning of the optical connectors
where appropriate. All of the SG4000 optical modules are equipped with SC/APC connectors but
may be ordered with SC to E2000 adaptors.
SG4000 Optical Modules
The forward path optical modules include:
SG4-R forward path optical receiver
The return path optical transmitter modules include:
SG4-IFPT — isolated Fabry-Perot, 0.4 mW, 1310 nm
SG4-EIFPT — enhanced, isolated Fabry-Perot, 1.0 mW, 1310 nm
SG4-DFBT and SG4-DFBT3 — isolated Distributed Feedback, 1.0 and 2.0 mW respectively,
1310 nm
SG4-DFBT3-*-CWDM — isolated Distributed Feedback, 2.0 mW, eight 1550 nm
wavelengths
SG4-DRT-2X — 6.3 mW, DWDM ITU channel, 2X TDM digital return
Installing SG4000 Optical Modules
The SG4000 optical modules design enables you to install them while the node is in service. The
module’s flat bottom provides an excellent thermal transfer surface and has locating holes that
align with guide pins in the lid of the node.
To install an optical module:
1 Determine the proper slot for the module by referring to Section 3, “Bench Setup and
Operation,” and Figure 3-2.
2 Position the module in the appropriate slot and press gently on the casting until it is fully
seated.
3 Tighten the three 1/4 inch mounting bolts to 8–12 in-lbs to secure the module in the SG4000
lid.
4 Remove the dust covers from the service cable connector and the module’s optical connector.
5 Carefully clean the optical connector using a suitable optical cleaning kit.
6 If necessary, check the optical power levels.
7 Connect the service cable to the module’s optical connector.
8 Attach the appropriate RF cabling to the optics module.
9 Check and align the RF levels in accordance with system requirements and procedures.
Vista de pagina 72