Overview 2-13
SG4000 Installation and Operation Manual
board. A flexible power-distribution design enables you to power the node from any of the six
RF/AC ports. Using fuses and shunts, you can configure the node to distribute power to the
remaining active ports. You can also power the node locally through either end while a second
cable-plant power supply loops through the other end of the node.
You can power the SG4000 from either 60 VAC or 90 VAC system power supplies. There is no
voltage selection jumper to relocate. The 20-ampere fuses, installed at the factory, provide
power passing to additional amplifiers. Section 3, “Bench Setup and Operation,” Powering the
Node, discusses fusing options that are also diagrammed in Figure 3-36. Figures 3-37 and 3-38
illustrate the location of the fuses.
Port Entry
The SG4000 housing base features six RF/AC ports that are physically identical. You can power
the node from any of these ports and use any port to support an RF module for custom
installations.
The SG4000 port entry seizure mechanism contains a 1/16-inch hex-head screw that travels
within a threaded ferrule to secure the connector.
This screw is captive and should not be backed out by using excessive force.
Figure 2-9 illustrates a top view of the port entry board and the seizure mechanism.
Figure 2-9
Port entry board – seizure mechanism
Seizure mechanism