Bench Setup and Operation 3-13
SG4000 Installation and Operation Manual
Figure 3-12 illustrates the forward segmented 2X board. Jumper J4 is shown in the normal
position that enables signal flow to each output connector. When configuring for a single output,
move
J4 to the lower position, thereby terminating output connector J5 (OUT 1).
Figure 3-12
Forward segmented 2X board
OUT 2
OUT 1
RX
J4
N
O
R
M
T
E
R
M
Figure 3-13 illustrates the signal flow through the forward segmented 2X board. Loss is
measured at 870 MHz.
Figure 3-13
Forward segmented 2X – signal flow
Loss = 8.7 dB
J4
-4.5 dB
-4.0 dB
Rx
Out 1
Out 2
To set up the forward segmented 2X option:
1 Confirm that an SG4-R/* receiver is installed in lid slots 1 and 7.
2 Confirm that two forward segment 2X boards are installed in the forward configuration
board locations 1 and 4, as illustrated in Figure 3-11.
3 Install an RF cable from each SG4-R receiver to the respective forward segment 2X board.
The RF cable should be approximately five inches long and have black boots on the
connector signifying the forward path.
4 Connect the appropriate forward RF cables from the SG4-RF modules to the forward
segment 2X board.
5 Position jumper J4 as required for the number of active outputs you are using.
In a typical installation, the RF modules in Ports 1 and 3 are connected to the forward
segment 2X board in configuration location 1. The RF modules in Ports 4 and 6 are
connected to the forward segment 2X board in configuration location 4.
6 Ensure that the PIC cable is properly connected to the lid router board and center
power-distribution board in the node base.
7 Route the fiber service cable into the node and fiber tray.