5 - 28 Omnii (Windows Embedded Hand-Held 6.5) User Guide
Troubleshooting
Improper Battery Storage
Storing batteries in the gang charger for extended periods (more than a week or two) is not recommended.
Lithium-ion batteries lose capacity if they are maintained at full charge for long periods of time. See the battery
handling recommendations in “The Battery” on page 1-5.
Power Self-test LEDs Don’t Light Up
The charge slot LEDs will light up briefly when first applying power indicating the self-test mode. When
applying power to the unit, all the LEDs will light up. Yellow will show up in the 25% LED for each bay; green for
other LEDs. Then bay #1 will blink a binary representation of the firmware version (V09 = 1001). If the self-test
is not evident:
Remove all batteries, and unplug the charger.
Connect another device to the mains outlet to ensure there is power.
Remove the IEC mains power cable from the charger, and check it for damage.
Reconnect the mains cable in the charger and mains outlet.
Indicator Does Not Light When Battery Installed
Remove the battery, and clean the contacts on the battery and the charge slot.
Reinstall the battery, and check that it
is fully seated in the slot.
Inspect the charge slot contacts for damage (ar
e they bent, flattened, twisted or broken).
Try inserting a battery that you know to be working in the charger slot.
Reconnect the mains power cable, and check that th
e slot indicator flashes at power up.