C - 10 Omnii (Windows Embedded Hand-Held 6.5) User Guide
Short Code
When enabled, this parameter allows scanning of short I 2 of 5 barcodes (2 characters). When disabled, these
sho
rt barcodes are rejected.
Enabling “Short Code” may reduce the robustness of the
decoding since the hand-held must decode more
potential barcodes; it is therefore not recommended for general-purpose barcodes with 4 or more characters.
Verify
The value entered for this parameter determines the numbe
r of correct additional decodes required after the
initial decode, prior to a barcode being accepted. Higher values significantly increase the time it takes to
decode a barcode but also improve the reliability of the decoded barcode.
Security
This parameter controls the to
lerance for decoding edge-to-edge barcodes (Code 93, Code 128, UPC/EAN).
Lower values have a lower tolerance for misreads, but they also increase the time it takes to decode the
barcode. The default value of 30 is generally a good compromise setting.
The barcode symbologies for the scanner
are listed in table following.
Non-Decoded Barcode Symbologies
Code 39 Code 93 (disabled)
Code 128 Code 11 (disabled)
EAN 13 Interleaved 2 of 5 (disabled)
EAN 8 MSI Plessey (disabled)
UPC-A Discrete 2 of 5 (disabled)
UPC-E IATA 2 of 5 (disabled)
Codabar (disabled)
Comentarios a estos manuales