21 - 14 WiNG CLI Reference Guide
21.1.12 smart-ocs-monitoring
smart-rf-policy
Applies smart off channel scanning instead of dedicated detectors
Supported in the following platforms:
RFS7000
RFS6000
RFS4000
AP71xx
AP650
AP6511
AP6532
Syntax
smart-ocs-monitoring {extended-scan-frequency|frequency|
off-channel-duration|sample-count}
Parameters
Example
rfs7000-37FABE(config-smart-rf-policy-test)#smart-ocs-monitoring extended-scan-
frequency 2.4Ghz 9
rfs7000-37FABE(config-smart-rf-policy-test)#
rfs7000-37FABE(config-smart-rf-policy-test)#smart-ocs-monitoring sample-count 2.4Ghz
3
rfs7000-37FABE(config-smart-rf-policy-test)#
rfs7000-37FABE(config-smart-rf-policy-test)#smart-ocs-monitoring off-channel-
duration 2.4Ghz 25
rfs7000-37FABE(config-smart-rf-policy-test)#
{extended-scan-
frequency|frequency|
off-channel-duration|
sample-count}
extended-scan-frequency [2.4Ghz|5Ghz] <0-50> – Specifies the
frequency at which an extended scan is performed instead of a
neighbor only scan. Sets the number of trails from 0-50.
frequency [2.4Ghz|5Ghz] <1-120> – Specifies the frequency at which
the channel has to be switched. Sets the value in seconds from 1-120.
off-channel-duration [2.4Ghz|5Ghz] <20-150> – Specifies the duration
required to spend off channel. Sets the value in milliseconds from 20-
150
sample-count [2.4Ghz|5Ghz] <1-120> – Specifies the number of
samples collected before reporting to the Smart-RF master. Sets the
sample-count from 1-120.
NOTE: The commands clrscr, commit, end, exit, help, revert, service, show, write are
common commands across all chapters. For more information, see Chapter 5, COMMON
COMMANDS.